Air Receiver

Ceccato’s vertical air receivers offer a high-performance storage solution designed to maximize efficiency while minimizing your footprint. Ranging from 100L to 5000L, these tanks feature a space-saving vertical design that frees up valuable production area and helps lower overall energy costs.

Available in Painted, Galvanized, and Vitroflex finishes, they are built to withstand the demands of any industrial application. Click below to discover all the advantages Ceccato brings to your compressed air system.

Why Your Compressed Air System Needs a Quality Receiver

User Benefits

Pressure stabilization

  • Beneficial for the pneumatic tools using the compressed air

Storage function

  • For handling high air consumption

Improvement of the lifetime, reliability and functionality of your compressor

  • Pulsation reduction
  • Velocity reduction
  • Temperature reduction
  • Condensate separation

Functionalities

Suitable for any application using compressed air:

  • Storage function in order to handle high air consumption
  • Stabilize pressure peaks and provide a stable air flow
  • Perform a preliminary separation and removal of condensate

Technical Data & Capacity Options

Standard

Capacity (L)100200270500720900100015002000300040005000
Pressure (bar)1111111110.8111211.511.511.511.511.5
Diameter Ø37044650060075080080010001000120014501450
H tot (mm)117215701668205520302120231523052805296530703570
h (mm)124174170155150130115180180185180180
a3/4”1”1”1”1”1½”2”2”2”3”3”3”
b3/4”1”1”1”1”1½”2”2”2”3”3”3”
c3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/4”3/4”3/4”3/4”3/4”
d3/8”3/8”n.d.n.d.3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”
e1/2”1/2”1/2”2”2”2”2”1¼”1¼”1¼”1¼”1¼”
f1/2”1/2”1/2”2”2”2”2”1¼”1¼”1¼”1¼”1¼”
l (mm)298397599775895860745590595700780780
m (mm)99812221304156017051780168518602355241024302930
Kit type included1234467BBBnot incl.not incl.
Weight (kg)375162127180200204278352537802923
Norm & Standards2014/29/UE2014/68/EU (PED)
Capacity (L)100200270500720900100015002000300040005000
Pressure (bar)1111111110.81111.511.511.511.511.511.5
Diameter Ø37043050060079079079010001000120014501450
H tot (mm)122915301685207718632213234523052805296530703570
h (mm)176135192174200200200180180185180180
a3/4”3/4”3/4”1½”1½”2”2”2”2”3”3”3”
b3/4”3/4”3/4”1½”1½”2”2”2”2”3”3”3”
c3/8”3/4”3/4”3/4”3/4”3/4”3/4”3/4”3/4”3/4”3/4”3/4”
d3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”
e2”2”2”1¼”1¼”1¼”1¼”1¼”1¼”1¼”1¼”1¼”
f2”2”2”1¼”1¼”1¼”1¼”1¼”1¼”1¼”1¼”1¼”
l (mm)447397442689690800725590595700780780
m (mm)105512801422168914401800172518602355241024302930
Kit type included1AAAAABBBBnot incl.not incl.
Weight (kg)4055661431842092243063875918821025
Norm & Standards2014/29/UE2014/68/EU (PED)
Capacity (L)100200270500720900100015002000300040005000
Pressure (bar)N.A.11111110.81111.511.511.511.511.511.5
Diameter ØN.A.43050060079079079010001000120014501450
H tot (mm)N.A.15301685207718632213234523052805296530703570
h (mm)N.A.135192174200200200180180185180180
aN.A.3/4”3/4”1½”1½”2”2”2”2”3”3”3”
bN.A.3/4”3/4”1½”1½”2”2”2”2”3”3”3”
cN.A.3/4”3/4”3/4”3/4”3/4”3/4”3/4”3/4”3/4”3/4”3/4”
dN.A.3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”3/8”
eN.A.2”2”1¼”1¼”1¼”1¼”1¼”1¼”1¼”1¼”1¼”
fN.A.2”2”1¼”1¼”1¼”1¼”1¼”1¼”1¼”1¼”1¼”
l (mm)N.A.397442689690800725590595700780780
m (mm)N.A.12801422168914401800172518602355241024302930
Kit type includedN.A.AAAAABBBBnot incl.not incl.
Weight (kg)N.A.5060130167190204278352537802932
Norm & Standards2014/29/UE2014/68/EU (PED)

High Pressure

Capacity (L)50010002000300040005000
Pressure (bar)161616161616
Diameter Ø6008001000120014301430
H tot (mm)205523152810293031103610
h (mm)155115175170190190
a1”2”2”2”2”2”
b1”2”2”2”2”2”
cn.d.3/8”3/4”3/4”3/4”3/4”
d3/8”3/8”3/8”3/8”3/8”3/8”
e2”2”2”2”2”2”
f2”2”2”2”2”2”
l (mm)775745565645765765
m (mm)156016852340237024502950
Kit type included58CCnot incl.not incl.
Weight (kg)1592464906209051055
Norm & Standards2014/68/EU (PED)
Capacity (L)50010002000300040005000
Pressure (bar)161616161616
Diameter Ø6007901000120014301430
H tot (mm)212023652810293031103610
h (mm)175200175170190190
a2”2”2”2”2”2”
b2”2”2”2”2”2”
c3/4”3/4”3/4”3/4”3/4”3/4”
d3/8”3/8”3/8”3/8”3/8”3/8”
e2”2”2”2”2”2”
f2”2”2”2”2”2”
l (mm)485725565645765765
m (mm)174517252340237024502950
Kit type includedCCCCnot incl.not incl.
Weight (kg)1763085396829951160
Norm & Standards2014/68/EU (PED)
Capacity (L)50010002000300040005000
Pressure (bar)161616161616
Diameter Ø6007901000120014301430
H tot (mm)212023652810293031103610
h (mm)175200175170190190
a2”2”2”2”2”2”
b2”2”2”2”2”2”
c3/4”3/4”3/4”3/4”3/4”3/4”
d3/8”3/8”3/8”3/8”3/8”3/8”
e2”2”2”2”2”2”
f2”2”2”2”2”2”
l (mm)485725565645765765
m (mm)174517252340237024502950
Kit type includedCCCCnot incl.not incl.
Weight (kg)1602804906209051055
Norm & Standards2014/68/EU (PED)

Choosing the Right Vessel Finish for Your Environment

Selecting the appropriate coating is essential for the lifespan of your pressure vessel and the quality of your compressed air. At Apex Air Malaysia, we offer three specialized finishes tailored to different industrial demands:

Painted Air Receivers (Standard Protection)

Best for: Indoor manufacturing plants and dry environments. Our painted vessels are the industry standard for most applications where the air receiver is not exposed to extreme weather. The high-quality external paint job ensures reliable protection against atmospheric corrosion, making it a cost-effective solution for standard factory setups.

Galvanized (Zinc) Air Receivers (Maximum Durability)

Best for: High-humidity regions, coastal areas, or outdoor installations. Galvanization is the ultimate defense against rust. Through a process where the vessel is completely submerged in a liquid zinc bath, we ensure the coating adheres perfectly to both the internal and external surfaces of the tank.

  • The Benefit: Full protection of the steel, even in Malaysia’s tropical climate, significantly extending the tank’s service life.

Vitrified (Vitroflex) Air Receivers (Hygienic & Premium)

Best for: Food & Beverage, Pharmaceuticals, and Clean-room applications. These vessels undergo a specialized vitreous enamel treatment, making them completely resistant to water and steam.

  • The Process: After being baked at 850°C, the enamel creates an inorganic link with the metal surface.

  • The Result: A surface that no longer absorbs water and provides 100% protection against corrosion. It is the ideal choice when “perfectly clean air” is an absolute prerequisite for your production line.

How to Size Your Air Receiver Tank?

  • Formula 1: 1/4 x Free Air Delivery (m³/min).
  • Formula 2: Motor Power (HP) x 30 = Liters.

Frequently Asked Questions (FAQs)

An air receiver tank stabilizes air pressure, stores compressed air, and reduces compressor cycling, helping the system run more efficiently and reliably.

Sizing depends on compressor capacity, air demand patterns, and peak usage periods. Most users choose a tank with storage volume 6 to 10 times the compressor’s flow rate.

A vertical tank saves floor space and fits well in tight production areas while still providing sufficient air storage and stable pressure control.

Routine tasks include draining condensate, checking safety valves, inspecting internal corrosion, and ensuring the tank meets local safety standards.

It reduces sudden pressure fluctuations, lowers energy consumption, supports consistent airflow during peak demand, and extends compressor lifespan.